电话:
+86 (0512) 65829739
传真:
+86 (010) 6788 5057
电子邮件:
orders@antibodies-online.cn

猪 anti-人 IgE (Fc Region) Antibody (FITC)

ELISA, IF, ICC, IHC (fro) Polyclonal FITC
产品编号 ABIN458194
发货至: 中国
  • 抗原 See all IgE products
    IgE
    抗原表位
    • 29
    • 19
    • 19
    • 1
    • 1
    Fc Region
    适用
    • 52
    • 30
    • 11
    • 9
    • 5
    • 4
    • 2
    • 1
    宿主
    • 59
    • 22
    • 10
    • 10
    • 3
    • 1
    克隆类型
    • 64
    • 32
    多克隆
    标记
    • 30
    • 17
    • 16
    • 15
    • 7
    • 6
    • 4
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    FITC
    应用范围
    • 57
    • 39
    • 28
    • 21
    • 20
    • 15
    • 12
    • 10
    • 10
    • 8
    • 8
    • 6
    • 5
    • 3
    • 3
    • 3
    • 1
    • 1
    • 1
    • 1
    ELISA, Immunofluorescence (IF), Immunocytochemistry (ICC), Immunohistochemistry (Frozen Sections) (IHC (fro))
    特异性
    Fluorescein isothiocyanate-conjugated IgG fraction of polyclonal Swine antiSerum to Human IgE Fc specific.
    交叉反应 (详细)
    This immunoconjugate is not species-specific since inter-species cross-reactivity is a normal feature of antisera to immunoglobulins. Cross-reactivity of this conjugate has not been tested in detail.
    产品特性
    The reactivity of the antiserum is directed to the Fc subunit of the IgE molecule, which expresses strict (class) specificity. In immunoelectrophoresis and radial in immunodiffusion using various antiserum concentrations against human serum, a single precipitin line has been obtained which shows a reaction of identity with the precipitin lines obtained with the purified IgE used as immunogens. It does not react with IgG including all subclasses, IgG/Fab fragments, IgM and IgA or any non-Ig protein in human serum, as tested by immunoelectrophoresis and double radial immunodiffusion. The antiserum also react with membrane-bound IgE in peripheral blood cells as tested by immunofluorescence microscopy. In immunocytochemical and immunohistochemical staining for the detection of IgE at the cellular and subcellular level by staining of appropriately treated cell and tissue substrates, to identify and measure IgE in human serum or other body fluids. This immunoconjugate is not pre-diluted. The optimum working dilution of each conjugate should be established by titration before being used. Excess labelled antibody must be avoided because it may cause high unspecific background staining and interfere with the specific signal.
    纯化方法
    Purified
    免疫原
    Pools of purified homogenous IgE isolated from human serum. Freund's complete adjuvant is used in the first step of the immunization procedure.
  • 应用备注
    ELISA,Immunocytochemistry,Immunohistochemistry (frozen),(In)direct immunofluorescence.
    限制
    仅限研究用
  • 状态
    Lyophilized
    溶解方式
    It is reconstituted by adding 1 mL sterile distilled water, spun down to remove insoluble particles, divided into small aliquots, frozen and stored at or below -20 °C.FITC-coupled purified hyperimmune swine IgG lyophilized from a solution in phosphate buffered saline (PBS, pH 7.2). No preservative added, as it may interfere with the antibody activity. It is reconstituted by adding 1 mL sterile distilled water, spun down to remove insoluble particles, divided into small aliquots, frozen and stored at or below -20 °C.
    缓冲液
    FITC-coupled purified hyperimmune swine IgG lyophilized from a solution in phosphate buffered saline (PBS, pH 7.2). No preservative added, as it may interfere with the antibody activity.
    储存液
    Without preservative
    储存条件
    RT,4 °C,-20 °C
    储存方法
    The lyophilized conjugate is shipped at ambient temperature and may be stored at +4°C, prolonged storage at or below -20°C. Prior to use, an aliquot is thawed slowly at ambient temperature, spun down again and used to prepare working dilutions by adding sterile phosphate buffered saline (PBS, pH 7.2). Repeated thawing and freezing should be avoided. Working dilutions should be stored at +4°C, not refrozen, and preferably used the same day. If a slight precipitation occurs upon storage, this should be removed by centrifugation. It will not affect the performance of the immunoconjugate.
  • 抗原
    IgE
    Abstract
    IgE 产品
You are here:
客服