APOE ELISA 试剂盒

APOE 适用: Pig Colorimetric Competition ELISA 31.25 ng/mL - 2000 ng/mL Plasma, Serum, Tissue Homogenate
产品编号 ABIN6975322
发货至: 中国
  • 抗原 See all APOE ELISA试剂盒
    APOE (Apolipoprotein E (APOE))
    适用
    • 11
    • 5
    • 5
    • 4
    • 4
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    Pig
    检测方法
    Colorimetric
    实验类型
    Competition ELISA
    检测范围
    31.25 ng/mL - 2000 ng/mL
    最低检测浓度
    31.25 ng/mL
    应用范围
    ELISA
    原理
    For the quantitative determination of pig apolipoprotein E (Apo-E) concentrations in serum, plasma, tissue homogenates.
    样品类型
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    特异性
    This assay has high sensitivity and excellent specificity for detection of pig Apo-E. No significant cross-reactivity or interference between pig Apo-E and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between pig Apo-E and all the analogues, therefore, cross reaction may still exist.
    灵敏度
    7.81 ng/mL
    组件
    • Assay plate
    • Standard
    • HRP-conjugate (100 x concentrate)
    • Sample Diluent
    • HRP-conjugate Diluent
    • Wash Buffer (25 x concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip
  • Stop Solution
  • Adhesive Strip
  • Top Product
    Discover our top product APOE ELISA Kit
  • 应用备注
    Optimal working dilution should be determined by the investigator.
    样本量
    50 μL
    实验时间
    1 - 4.5 h
    板类型
    Pre-coated
    实验流程
    1. Prepare reagents, samples and standards as instructed.
    2. Set a Blank well without any solution.
    3. Add 50 µL standard or sample to each well.
    4. Add 50 µL HRP-conjugate (1x) to each well (Not to Blank well).
    5. Incubate 1 hour at 37 °C
    6. Aspirate and wash 5 times.
    7. Add 90 μL of TMB Substrate to each well. Incubate for 20 minutes at 37 °C. Protect from light.
    8. Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
    试剂准备
    1. HRP-conjugate (1x) - Centrifuge the vial before opening. HRP-conjugate requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-conjugate + 990 μL of HRP-conjugate Diluent.
    2. Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
    3. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 2000 ng/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 150 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (2000 ng/mL). Sample Diluent serves as the zero standard (0 ng/mL).
    Note:
    • Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
    • Bring all reagents to room temperature (18-25 °C) before use for 30 min.
    • Prepare fresh standard for each assay. Use within 4 hours and discard after use.
    • Making serial dilution in the wells directly is not permitted.
    • Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
    • Distilled water is recommended to be used to make the preparation for reagents or samples. Contaminated water or container for reagent preparation will influence the detection result.
    样品制备
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Note:
    Recommend to dilute the serum or plasma samples with Sample Diluent(1:200) before test. The suggested 200-fold dilution can be achieved by adding 5 μL sample to 45 μL of Sample Diluent. Complete the 200-fold dilution by adding 15 μL of this solution to 285 μL of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments.
    实验精密度
    Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
    Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess.
    限制
    仅限研究用
  • 储存条件
    4 °C,-20 °C
    储存方法
    Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If don't make recent use, better keep it store at HRP-conjugate -20°C. Opened kit HRP-conjugate Diluent Sample Diluent May be stored for up to 1 month at 2 - 8°C. Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
    有效期
    6 months
  • 抗原 See all APOE ELISA试剂盒
    APOE (Apolipoprotein E (APOE))
    别名
    apolipoprotein E (Apo-E) (APOE 产品)
    别名
    ad2 ELISA Kit, apoprotein ELISA Kit, im:7036787 ELISA Kit, wu:fb69a05 ELISA Kit, zgc:110064 ELISA Kit, apoe ELISA Kit, AI255918 ELISA Kit, AD2 ELISA Kit, LDLCQ5 ELISA Kit, LPG ELISA Kit, APOEA ELISA Kit, Apo-E ELISA Kit, apolipoprotein E ELISA Kit, apolipoprotein Ea ELISA Kit, apoe ELISA Kit, apoea ELISA Kit, Apoe ELISA Kit, APOE ELISA Kit
    背景

    Abbreviation: APOE

    Alias: AD2, LDLCQ5, LPG, MGC1571, apolipoprotein E3

    UniProt
    P18650
    途径
    Regulation of Cell Size, Lipid Metabolism
You are here:
客服