电话:
+86 (0512) 65829739
传真:
+86 (010) 6788 5057
电子邮件:
orders@antibodies-online.cn

EPH Receptor B2 IQ-ELISA 试剂盒

EPHB2 适用: 人 qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
产品编号 ABIN6386135
发货至: 中国
  • 抗原 See all EPH Receptor B2 (EPHB2) IQ-ELISA Kits
    EPH Receptor B2 (EPHB2)
    适用
    • 4
    • 1
    检测方法
    qPCR
    实验类型
    Sandwich ELISA
    应用范围
    ELISA
    原理
    Human Immunoquantitative (PCR-Based) EphB2 ELISA Kit for cell culture supernatants, plasma, and serum samples.
    样品类型
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    产品特性
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    组件
    • EphB2 Microplate (Item A): 96 well PCR plate coated with anti-Human EphB2
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human EphB2
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for EphB2 (Item F): 2 vials of a 4x concentrated solution of anti-Human EphB2 affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    试剂未包括
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Featured
    Discover our best selling EPHB2 ELISA Kit
    Top Product
    Discover our top product EPHB2 ELISA Kit
  • 应用备注
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    说明

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    样本量
    25 µL
    板类型
    Pre-coated
    实验流程
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    限制
    仅限研究用
  • 储存条件
    4 °C,-20 °C,-80 °C
    储存方法
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    有效期
    6 months
  • 抗原 See all EPH Receptor B2 (EPHB2) IQ-ELISA Kits
    EPH Receptor B2 (EPHB2)
    别名
    EphB2 (EPHB2 产品)
    别名
    CAPB IQ-ELISA Kit, DRT IQ-ELISA Kit, EK5 IQ-ELISA Kit, EPHT3 IQ-ELISA Kit, ERK IQ-ELISA Kit, Hek5 IQ-ELISA Kit, PCBC IQ-ELISA Kit, Tyro5 IQ-ELISA Kit, ERK2 IQ-ELISA Kit, ERT1 IQ-ELISA Kit, MAPK2 IQ-ELISA Kit, P42MAPK IQ-ELISA Kit, PRKM1 IQ-ELISA Kit, PRKM2 IQ-ELISA Kit, p38 IQ-ELISA Kit, p40 IQ-ELISA Kit, p41 IQ-ELISA Kit, p41mapk IQ-ELISA Kit, RGD1564232 IQ-ELISA Kit, Cek5 IQ-ELISA Kit, Drt IQ-ELISA Kit, ETECK IQ-ELISA Kit, Erk IQ-ELISA Kit, Nuk IQ-ELISA Kit, Prkm5 IQ-ELISA Kit, Qek5 IQ-ELISA Kit, Sek3 IQ-ELISA Kit, cek5 IQ-ELISA Kit, ephb2 IQ-ELISA Kit, xEphB2 IQ-ELISA Kit, si:ch73-160e9.1 IQ-ELISA Kit, tpx2 IQ-ELISA Kit, wu:fb09e10 IQ-ELISA Kit, wu:fc64a03 IQ-ELISA Kit, wu:fi18g12 IQ-ELISA Kit, zgc:112296 IQ-ELISA Kit, EPH receptor B2 IQ-ELISA Kit, mitogen-activated protein kinase 1 IQ-ELISA Kit, Eph receptor B2 IQ-ELISA Kit, EPH receptor B2 L homeolog IQ-ELISA Kit, eph receptor B2a IQ-ELISA Kit, eph receptor B2b IQ-ELISA Kit, EPHB2 IQ-ELISA Kit, MAPK1 IQ-ELISA Kit, Ephb2 IQ-ELISA Kit, ephb2.L IQ-ELISA Kit, ephb2a IQ-ELISA Kit, ephb2b IQ-ELISA Kit
    基因ID
    2048
    UniProt
    P29323
    途径
    RTK signaling, Regulation of long-term Neuronal Synaptic Plasticity, S100 Proteins
You are here: