IL-13 ELISA 试剂盒
-
- 抗原 See all IL-13 (IL13) ELISA试剂盒
- IL-13 (IL13) (Interleukin 13 (IL13))
-
适用
- 大鼠
- 检测方法
- Colorimetric
- 实验类型
- Sandwich ELISA
- 应用范围
- ELISA
- 原理
- Rat IL-13 ELISA Kit for cell and tissue lysate samples.
- 样品类型
- Cell Lysate, Tissue Lysate
- Analytical Method
- Quantitative
- 特异性
- The antibody pair provided in this kit recognizes rat IL-13.
- 交叉反应 (详细)
- This ELISA kit shows no cross-reactivity with any of the following cytokines tested: rat CINC-2, CINC-3, CNTF, Fractalkine, IL-1alpha, IL-1beta, IL-4, IL-6, IL-10, GM-CSF, IFN-gamma, Leptin, Lix, MCP-1, MIP-3alpha, beta- NGF, TIMP-1, VEGF.
- 灵敏度
- 20 pg/mL
- 产品特性
-
- Strip plates and additional reagents allow for use in multiple experiments
- Quantitative protein detection
- Establishes normal range
- The best products for confirmation of antibody array data
- 组件
-
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Stop Solution
- Assay Diluent(s)
- Lyophilized Standard
- Biotinylated Detection Antibody
- Streptavidin-Conjugated HRP
- TMB One-Step Substrate
- 试剂未包括
-
- Distilled or deionized water
- Precision pipettes to deliver 2 μL to 1 μL volumes
- Adjustable 1-25 μL pipettes for reagent preparation
- 100 μL and 1 liter graduated cylinders
- Tubes to prepare standard and sample dilutions
- Absorbent paper
- Microplate reader capable of measuring absorbance at 450nm
- Log-log graph paper or computer and software for ELISA data analysis
- Cell lysate buffer
- Featured
- Discover our best selling IL13 ELISA Kit
- Top Product
- Discover our top product IL13 ELISA Kit
-
-
- 样本量
- 100 μL
- 板类型
- Pre-coated
- 实验流程
-
- Prepare all reagents, samples and standards as instructed in the manual.
- Add 100 μL of standard or sample to each well.
- Incubate 2.5 h at RT or O/N at 4 °C.
- Add 100 μL of prepared biotin antibody to each well.
- Incubate 1 h at RT.
- Add 100 μL of prepared Streptavidin solution to each well.
- Incubate 45 min at RT.
- Add 100 μL of TMB One-Step Substrate Reagent to each well.
- Incubate 30 min at RT.
- Add 50 μL of Stop Solution to each well.
- Read at 450 nm immediately.
- 试剂准备
-
- Bring all reagents and samples to room temperature (18 - 25 °C) before use.
2. Sample dilution: Tissue lysate and cell lysate sample should be diluted at least 5-fold with 1x Sample Diluent Buffer.
3. Sample Diluent Buffer (Item D) and Assay Diluent (Item E) should be diluted 5-fold with deionized or distilled water before use.
4. Preparation of standard: Briefly spin the vial of Item C. Add 400 µL 1x Sample Diluent Buffer (Item D, should be diluted 5-fold with deionized or distilled water before use) into Item C vial to prepare a 100 ng/mL standard. Dissolve the powder thoroughly by a gentle mix. Add 100 µL IL-13 standard from the vial of Item C, into a tube with 400 µL Sample Diluent Buffer to prepare a 20,000 pg/mL stock standard solution. Pipette 400 µL 1x Sample Diluent Buffer into each tube. Use the stock standard solution to produce a dilution series . Mix each tube thoroughly before the next transfer. 1x Sample Diluent Buffer serves as the zero standard (0 pg/mL). 200 µL 100 µL standard + 400 µL 200myl 200 µL 200 µL 200 µL 200 µL 20,000 6,667 2,222 740.7 246.9 82.30 27.43 0 pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL
5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to yield 400 ml of 1x Wash Buffer.
6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µL of 1x Assay Diuent into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diuent and used in step 4 of Part VI Assay Procedure.
7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) before use. HRP-Streptavidin concentrate should be diluted 700-fold with 1x Assay Diuent. For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 20 µL of HRP-Streptavidin concentrate into a tube with 14 ml 1x Assay Diluent to prepare a 700-fold diluted HRP- Streptavidin solution (don't store the diluted solution for next day use). Mix well.
8. Cell lysate buffer should be diluted 2-fold with deionized or distilled water (for cell lysate and tissue lysate). VI. ASSAY PROCEDURE: 1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate.
2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4 °C with gentle shaking.
3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 myl) using a multi-channel Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking.
5. Discard the solution. Repeat the wash as in step
6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking.
7. Discard the solution. Repeat the wash as in step
8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking.
9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately. VII. ASSAY PROCEDURE SUMMARY 1. Prepare all reagents, samples and standards as instructed.
2. Add 100 µL standard or sample to each well. Incubate 2.5 hours at room temperature or over night at 4 °C.
3. Add 100 µL prepared biotin antibody to each well. Incubate 1 hour at room temperature.
4. Add 100 µL prepared Streptavidin solution. Incubate 45 minutes at room temperature.
5. Add 100 µL TMB One-Step Substrate Reagent to each well. Incubate 30 minutes at room temperature.
6. Add 50 µL Stop Solution to each well. Read at 450 nm immediately.
- Bring all reagents and samples to room temperature (18 - 25 °C) before use.
- 实验流程
-
- Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate.
2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4 °C with gentle shaking.
3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 myl) using a multi-channel Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking.
5. Discard the solution. Repeat the wash as in step
6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking.
7. Discard the solution. Repeat the wash as in step
8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking.
9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately.
- Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate.
- 结果分析
-
Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.
Typical Data: These standard curves are for demonstration only. A standard curve must be run with each assay. Sample Diluent Buffer Rat IL-13 concentration (pg/mL) O D =4 50 (n m ) 0.01 0.1 1 10 10 100 1,000 10,000 100,000
Sensitivity: The minimum detectable dose of IL-13 is typically less than 20 pg/mL.
Recovery: Recovery was determined by spiking various levels of Rat IL-13 into tissue lysate and cell lysate. Mean recoveries are as follows: Sample Type Average % Recovery Range ( %) Tissue lysate 107.8 81-135 Cell lysate 120.4 80-139
Linearity: Sample Type Tissue Cell Lysate lysate 1:2 Average % of 134.3 123.2 Expected Range ( %) 122-145 114-132 1:4 Average % of 139.3 104.5 Expected Range ( %) 123-146 95-112
Reproducibility: Intra-Assay: CV<10 % Inter-Assay: CV<12 % - 实验精密度
- Intra-Assay: CV< 10 % Inter-Assay: CV< 12 %
- 限制
- 仅限研究用
-
- 注意事项
- Avoid repeated freeze-thaw cycles.
- 储存条件
- -20 °C
- 储存方法
- The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
- 有效期
- 6 months
-
-
Blocking KV1.3 channels inhibits Th2 lymphocyte function and treats a rat model of asthma." in: The Journal of biological chemistry, Vol. 289, Issue 18, pp. 12623-32, (2014) (PubMed).
: "Interleukin-13/-4-induced oxidative stress contributes to death of hippocampal neurons in aβ1-42-treated hippocampus in vivo." in: Antioxidants & redox signaling, Vol. 16, Issue 12, pp. 1369-83, (2012) (PubMed).
: "
-
Blocking KV1.3 channels inhibits Th2 lymphocyte function and treats a rat model of asthma." in: The Journal of biological chemistry, Vol. 289, Issue 18, pp. 12623-32, (2014) (PubMed).
-
- 抗原 See all IL-13 (IL13) ELISA试剂盒
- IL-13 (IL13) (Interleukin 13 (IL13))
- 别名
- IL-13 (IL13 产品)
- 别名
- IL13 ELISA Kit, IL-13 ELISA Kit, P600 ELISA Kit, Il-13 ELISA Kit, L13 ELISA Kit, interleukin 13 ELISA Kit, IL13 ELISA Kit, Il13 ELISA Kit
- 背景
- Interleukin-13 (IL-13) (T-cell activation protein P600)
- 基因ID
- 116553
- UniProt
- P42203
- 途径
- JAK/STAT Signaling, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, Proton Transport
-