XPC CLIA Kit
-
- 抗原 See all XPC CLIA Kits
- XPC (Xeroderma Pigmentosum, Complementation Group C (XPC))
-
适用
- 人
- 检测方法
- Chemiluminescent
- 实验类型
- Sandwich ELISA
- 检测范围
- 156.25 pg/mL - 10000 pg/mL
- 最低检测浓度
- 156.25 pg/mL
- 应用范围
- ELISA
- 样品类型
- Tissue Homogenate
- Analytical Method
- Quantitative
- 特异性
- This assay has high sensitivity and excellent specificity for detection of Xeroderma Pigmentosum, Complementation Group C (XPC). No significant cross-reactivity or interference between Xeroderma Pigmentosum, Complementation Group C (XPC) and analogues was observed.
- 灵敏度
- 5.46 pg/mL
- Top Product
- Discover our top product XPC ELISA Kit
-
-
- 说明
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- 实验时间
- 2 - 3 h
- 板类型
- Pre-coated
- 实验流程
- The microplate provided in this kit has been pre-coated with an antibody specific to Xeroderma Pigmentosum, Complementation Group C (XPC). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Xeroderma Pigmentosum, Complementation Group C (XPC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Xeroderma Pigmentosum, Complementation Group C (XPC) level in the sample or standard.,
- 实验精密度
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Xeroderma Pigmentosum, Complementation Group C (XPC) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Xeroderma Pigmentosum, Complementation Group C (XPC) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - 限制
- 仅限研究用
-
- 注意事项
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- 储存条件
- 4 °C,-20 °C
- 储存方法
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- 有效期
- 4-8 months
-
- 抗原 See all XPC CLIA Kits
- XPC (Xeroderma Pigmentosum, Complementation Group C (XPC))
- 别名
- Xeroderma Pigmentosum, Complementation Group C (XPC 产品)
- 别名
- RAD4 CLIA Kit, XP3 CLIA Kit, XPCC CLIA Kit, XPC complex subunit, DNA damage recognition and repair factor CLIA Kit, xeroderma pigmentosum, complementation group C CLIA Kit, XPC CLIA Kit, Xpc CLIA Kit
- 背景
-
Gene Name: Xeroderma Pigmentosum, Complementation Group C
Gene Aliases: XP-C, XP3, XPCC, RAD4, Xeroderma Pigmentosum Group C Protein, DNA repair protein complementing XP-C cells
- 途径
- p53 Pathway, DNA Damage Repair
-