ADCY2 ELISA 试剂盒
-
- 抗原 See all ADCY2 ELISA试剂盒
- ADCY2 (Adenylate Cyclase 2 (Brain) (ADCY2))
- 适用
- 人
- 检测方法
- Colorimetric
- 实验类型
- Sandwich ELISA
- 检测范围
- 0.312 ng/mL - 20 ng/mL
- 最低检测浓度
- 0.312 ng/mL
- 应用范围
- ELISA
- 样品类型
- Cell Lysate, Tissue Homogenate
- Analytical Method
- Quantitative
- 特异性
- This assay has high sensitivity and excellent specificity for detection of Adenylate Cyclase 2, Brain (ADCY2). No significant cross-reactivity or interference between Adenylate Cyclase 2, Brain (ADCY2) and analogues was observed.
- 灵敏度
- 0.126 ng/mL
- Featured
- Discover our best selling ADCY2 ELISA Kit
- Top Product
- Discover our top product ADCY2 ELISA Kit
-
-
- 说明
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- 实验时间
- 3 h
- 板类型
- Pre-coated
- 实验流程
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Adenylate Cyclase 2, Brain (ADCY2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Adenylate Cyclase 2, Brain (ADCY2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Adenylate Cyclase 2, Brain (ADCY2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Adenylate Cyclase 2, Brain (ADCY2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- 实验精密度
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adenylate Cyclase 2, Brain (ADCY2) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adenylate Cyclase 2, Brain (ADCY2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - 限制
- 仅限研究用
-
- 注意事项
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- 储存条件
- 4 °C,-20 °C
- 储存方法
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- 有效期
- 4-8 months
-
- 抗原 See all ADCY2 ELISA试剂盒
- ADCY2 (Adenylate Cyclase 2 (Brain) (ADCY2))
- 别名
- Adenylate Cyclase 2, Brain (ADCY2 产品)
- 别名
- ADCY2 ELISA Kit, mKIAA1060 ELISA Kit, AC2 ELISA Kit, HBAC2 ELISA Kit, adenylate cyclase 2 ELISA Kit, ADCY2 ELISA Kit, Adcy2 ELISA Kit
- 背景
-
Gene Name: Adenylate Cyclase 2, Brain
Gene Aliases: HBAC2, ATP pyrophosphate-lyase 2, Adenylate cyclase type II
- 基因ID
- 108
- UniProt
- Q08462
- 途径
- EGFR Signaling Pathway, Neurotrophin Signaling Pathway, Thyroid Hormone Synthesis, cAMP Metabolic Process, Myometrial Relaxation and Contraction, G-protein mediated Events, Interaction of EGFR with phospholipase C-gamma
-