SDCCAG3 ELISA 试剂盒

SDCCAG3 适用: 人 Colorimetric Sandwich ELISA 1.56-100 ng/mL Cell Culture Supernatant, Plasma, Serum
产品编号 ABIN454787
发货至: 中国
  • 抗原 See all SDCCAG3 ELISA试剂盒
    SDCCAG3 (serologically Defined Colon Cancer Antigen 3 (SDCCAG3))
    适用
    • 1
    • 1
    • 1
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    1.56-100 ng/mL
    最低检测浓度
    1.56 ng/mL
    应用范围
    ELISA
    原理
    This immunoassay kit allows for the for the in vitro quantitative determination of human colon cancer-specific antigen-3, CCSA-3 concentrations in cell culture supernates, serum, plasma and other biological fluids.
    样品类型
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Quantitative
    特异性
    This assay recognizes recombinant and natural human CCSA-3.
    交叉反应 (详细)
    No significant cross-reactivity or interference was observed.
    灵敏度
    < 0.39 ng/mL
    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest detectable concentration that could be differentiated from zero.
    产品特性
    Homo sapiens,Human,Serologically defined colon cancer antigen 3,Antigen NY-CO-3,SDCCAG3
    组件
    Reagent (Quantity): Assay plate (1), Standard (2), Sample Diluent (1x20ml), Assay Diluent A (1x10ml), Assay DiluentB 1 x 10ml Detection Reagent A (1x120µl), Detection Reagent B (1x120µl), Wash Buffer 1 x 30ml 2 (25 x concentrate) Substrate (1x10ml), Stop Solution (1x10ml)
    Featured
    Discover our best selling SDCCAG3 ELISA Kit
    Top Product
    Discover our top product SDCCAG3 ELISA Kit
  • 样本量
    100 μL
    板类型
    Pre-coated
    实验流程
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to CCSA-3. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for CCSA-3 and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3'5, 5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain CCSA-3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of CCSA-3 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    试剂准备

    Bring all reagents to room temperature before use. Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have completely dissolved. Dilute 30 mL of Wash Buffer Concentrate into deionized or distilled water to prepare 500 mL of Wash Buffer. Standard - Reconstitute the Standard with 1.0 mL of Sample Diluent. This reconstitution produces a stock solution of 100 ng/mL. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (100 ng/mL). The Sample Diluent serves as the zero standard (0 ng/mL). 3 Detection Reagent A and B - Dilute to the working concentration specified on the vial label using Assay Diluent A and B (1:100), respectively.

    样品收集
    Serum - Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at approximately 1000 x g. Remove serum and assay immediately or aliquot and store samples at -20 °C or -80 °C. Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000 x g at 2 - 8 °C within 30 minutes of collection. Store samples at -20 °C or -80 °C. Avoid repeated freeze-thaw cycles. Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20 °C or -80 °C. Avoid repeated freeze-thaw cycles. Note: Serum, plasma, and cell culture supernatant samples to be used within 7 days may be stored at 2-8C, otherwise samples must stored at -20 °C (≤ 3 months) or -80 °C (≤ 6 months) to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles. When performing the assay slowly bring samples to room temperature. It is recommended that all samples be assayed in duplicate.
    实验流程

    Allow all reagents to reach room temperature. All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Arrange and label required number of strips. Prepare all reagents, working standards and samples as directed in the previous sections.
    1. Add 100 uL of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37 °C.
    2. Remove the liquid of each well, don’t wash.
    3. Add 100 uL of Detection Reagent A working solution to each well. Incubate for 1 hour at 37°C. Detection Reagent A working solution may appear cloudy. Warm to room temperature and mix gently until solution appears uniform.
    4. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash by filling each well with Wash Buffer (350 uL) using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
    5. Add 100 uL of Detection Reagent B working solution to each well. Cover with a new adhesive strip.Incubate for 1 hours at 37 °C.
    6. Repeat the aspiration/wash as in step
    5. 7. Add 90 uL of Substrate Solution to each well. Incubate for 30 minutes at 37°C. Protect from light.
    8. Add 50 uL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
    9. Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
    Important Note:
    1. The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings. 4
    2. It is recommended that no more than 32 wells be used for each assay run if manual pipetting is used since pipetting of all standards, specimens and controls should be completed within 5 minutes. A full plate of 96 wells may be used if automated pipetting is available.
    3. Duplication of all standards and specimens, although not required, is recommended.
    4. When mixing or reconstituting protein solutions, always avoid foaming.
    5. To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
    6. To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
    7. Do not substitute reagents from one kit lot to another. Standard, conjugate a microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.

    结果分析

    Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the CCSA-3 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

    限制
    仅限研究用
  • 注意事项
    1. The kit should not be used beyond the expiration date on the kit label.
    2. Do not mix or substitute reagents with those from other lots or sources.
    3. If samples generate values higher than the highest standard, further dilute the samples with the Assay Diluent and repeat the assay. Any variation in standard diluent, operator, pipetting technique, washing technique,incubation time or temperature, and kit age can cause variation in binding.
    4. This assay is designed to eliminate interference by soluble receptors, ligands, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
    储存条件
    4 °C/-20 °C
    储存方法
    The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 °C upon being received. The other reagents can be stored at 4 °C.
  • 抗原 See all SDCCAG3 ELISA试剂盒
    SDCCAG3 (serologically Defined Colon Cancer Antigen 3 (SDCCAG3))
    别名
    SDCCAG3 (SDCCAG3 产品)
    别名
    NY-CO-3 ELISA Kit, C330016H24Rik ELISA Kit, C630038K21Rik ELISA Kit, si:dkey-1o2.3 ELISA Kit, serologically defined colon cancer antigen 3 ELISA Kit, SDCCAG3 ELISA Kit, Sdccag3 ELISA Kit, sdccag3 ELISA Kit
    背景
    Two colorectal cancer-specific proteins, colon cancer–specific antigen (CCSA)-3 and CCSA-4, have shown promise as markers for detecting both colorectal cancer and precancerous lesions. CCSA-3 and CCSA-4 displayed a high degree of accuracy in identifying patients with preneoplastic and neoplastic lesions.