电话:
+86 (0512) 65829739
传真:
+86 (010) 6788 5057
电子邮件:
orders@antibodies-online.cn

DHX58 ELISA 试剂盒

DHX58 适用: 人 Colorimetric Sandwich ELISA 15.63-1000 pg/mL Cell Culture Supernatant, Plasma, Serum
产品编号 ABIN3198476
发货至: 中国
  • 抗原 See all DHX58 ELISA试剂盒
    DHX58 (DEXH (Asp-Glu-X-His) Box Polypeptide 58 (DHX58))
    适用
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    15.63-1000 pg/mL
    最低检测浓度
    15.63 pg/mL
    应用范围
    ELISA
    原理
    This assay employs the quantitative sandwich enzyme immunoassay technique for quantitative detection.
    样品类型
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Quantitative
    特异性
    RLR, Human
    灵敏度
    1.41 pg/mL
    组件
    Plate, Standard, Diluent
    试剂未包括
    Microplate reader capable of measuring absorbance at 450 nm, with correction wavelength set at 570 nm or 630 nm.
    Pipettes and pipette tips.
    50 μL to 300 μL adjustable multichannel micropipette with disposable tips.
    Multichannel micropipette reservoir.
    Beakers, flasks, cylinders necessary for preparation of reagents.
    Deionized or distilled water.
    Polypropylene test tubes for dilution.
  • 样本量
    100 μL
    实验时间
    3 - 4 h
    板类型
    Pre-coated
    限制
    仅限研究用
  • 缓冲液
    Buffer contains: 0.02 % sodium azide
    储存液
    Sodium azide
    注意事项
    This product contains Sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.
    注意事项
    Intended for research use only and are not for use in diagnostic or therapeutic procedures.
    Treat all chemicals with caution because they can be potentially hazardous.
    It is recommended that this product is handled only by persons who have been trained in laboratory techniques and in accordance with the principles of good laboratory practice. Wear personal protection equipment such as laboratory coat, safety glasses and gloves.
    Avoid direct contact with skin or eyes. Wash immediately with water in the case of contact with skin or eyes. Avoid contact of skin or mucous membranes with kit reagents or specimens. See material safety data sheet(s) for specific advice.
    Pure water or deionized water must be used for reagent preparation.
    The Stop Solution provided with this kit is an acid solution. Wear personal protection equipment with caution.
    Do not expose kit reagents to strong light during storage and incubation.
    Rubber or disposable latex gloves should be worn while handling kit reagents or specimens.
    Avoid contact of substrate solution with oxidizing agents and metal.
    Avoid splashing or generation of aerosols.
    Use disposable pipette tips and/or pipettes to avoid microbial or cross-contamination of reagents or specimens which may invalidate the test.
    Use clean, dedicated reagent trays for dispensing the conjugate and substrate reagent.
    Exposure to acid inactivates the HRP and antibody conjugate.
    Substrate solution must be warmed to room temperature prior to use.
    Decontaminate and dispose specimens and all potentially contaminated materials as they could contain infectious agents. The preferred method of decontamination is autoclaving for a minimum of 1 hour at 121.5 °C.
    Liquid wastes not containing acid and neutralized waste may be mixed with sodium hypochlorite in volumes such that the final mixture contains 1.0 % sodium hypochlorite. Allow 30 minutes for effective decontamination. Liquid waste containing acid must be neutralized prior to the addition of sodium hypochlorite.
    All reagents including microplate, samples, standards and working solution should be warmed to room temperature before use.
    To obtain accurate results, using adhesive film to seal the plate during incubation is suggested.
    It is recommended that all samples and standards be assayed in duplicate.
    Avoid foaming when mixing or reconstituting solutions containing protein.
    To avoid cross-contamination, use separate reservoirs for each reagent and change pipette tips between each standard, sample and reagent.
    When using an automated plate washer, adding a 30 seconds soak period before washing step and/or rotating the plate between wash steps may improve assay precision.
    When pipetting reagents, maintain a consistent order of addition from well-to-well.
    Keep Substrate solution protected from direct strong light. Substrate Solution should turn to gradations of blue after a proper color development.
    Read absorbance within 30 minutes after adding stop solution.
    Take care not to scratch the inner surface of the microwells.
    储存条件
    4 °C
    储存方法
    Store kit reagents between 2 and 8 °C. Immediately after use remaining reagents should be returned to cold storage (2 to 8 °C).
    Expiry of the kit and reagents is stated on labels. Expiration date of the kit components can only be guaranteed if the components are stored properly, and if, in case of repeated use of one component, this reagent is not contaminated by the first handling.
    Unopened Kit: Store at 2 - 8 °C (See expiration date on the label).
    Opened/Reconstituted Reagents: Up to 1 month at 2 - 8 °C.
    Reconstituted Standard: Up to 1 month at ≤ -20 °C in a manual defrost freezer. Avoid repeated freeze-thaw cycles.
    Microplate Wells: Up to 1 month at 2 - 8 °C. Return unused strips to the foil pouch containing the desiccant pack, reseal along entire edge to maintain plate integrity. Provided this is within the expiration date of the kit
  • 抗原 See all DHX58 ELISA试剂盒
    DHX58 (DEXH (Asp-Glu-X-His) Box Polypeptide 58 (DHX58))
    别名
    RLR (DHX58 产品)
    别名
    MGC82787 ELISA Kit, DHX58 ELISA Kit, lgp2 ELISA Kit, D11LGP2 ELISA Kit, D11lgp2e ELISA Kit, LGP2 ELISA Kit, RLR-3 ELISA Kit, B430001I08Rik ELISA Kit, D11Lgp2e ELISA Kit, LPG2 ELISA Kit, Lgp2 ELISA Kit, RGD1310093 ELISA Kit, DEXH-box helicase 58 L homeolog ELISA Kit, DExH-box helicase 58 ELISA Kit, probable ATP-dependent RNA helicase DHX58 ELISA Kit, DEXH (Asp-Glu-X-His) box polypeptide 58 ELISA Kit, DEXH-box helicase 58 ELISA Kit, dhx58.L ELISA Kit, DHX58 ELISA Kit, dhx58 ELISA Kit, LOC100566102 ELISA Kit, Dhx58 ELISA Kit
    背景
    The prolactin receptor (PRLR), a cytokine receptor - encoded by a gene on chromosome 5p13-14 - interacts with prolactin as a transmembrane receptor. Thus it contains an extracellular region that binds prolactin, a transmembrane region, and a cytoplasmatic region.
    基因ID
    5618
    NCBI登录号
    NM_000949
    UniProt
    P16471